Permit-to-Work — Generic Template¶
Document Information
| Field | Value |
|---|---|
| Document Reference | FORM_PTW_01 |
| Issue Number | 1 |
| Issue Date | 4 May 2026 |
| Next Review | 4 May 2027 |
| Controlled By | Sean Ashton (HSQE Consultant) |
| Approved By | Aaron Mason, Managing Director |
What this is
A single AMWS Permit-to-Work template covering the three permit-controlled activities the company performs: excavation, hot work, and confined space. Cross-referenced from MS 2.9 (excavation), MS 2.24 (hot work) and MS 3.3 (confined space). Maps to Achilles UVDB B2.7.6 evidence test. The template is filled in for every relevant job; completed permits are filed against the job pack and retained per SOP 4.7 Control of Records.
When a permit is required¶
| Activity | Permit required? | Trigger |
|---|---|---|
| Excavation | Yes — always | Any breaking of the ground, regardless of depth, on a public-highway or third-party site |
| Hot work | Yes | Any work generating sparks, flame or heat that could ignite combustibles — welding, oxy-fuel cutting, grinding, brazing, soldering, blowtorch use |
| Confined space | Yes | Entry to any space meeting the Confined Spaces Regulations 1997 definition (manholes, chambers, tanks) |
| Other | Not normally | Routine surface works on AMWS sites — covered by RAMS only |
How to use¶
- Issuer (Site Supervisor or deputy) completes Sections 1–4 before work starts
- Worker(s) read, sign Section 5 — they own the permit on site
- On completion, both parties sign Section 6 → permit closed
- Closed permit attached to job pack; copy filed in
docs/audit-readiness/ptw-records/<YYYY-MM>/ptw-<jobref>.md
FORM_PTW_01 — copy this block into a fresh permit¶
# Permit-to-Work — <PTW number> — <Date>
| Field | Value |
|-------|-------|
| **Permit number** | PTW-<YYYY>-<###> |
| **Job reference** | <RAMS / job-pack ref> |
| **Site / location** | <site address + grid ref or postcode> |
| **Client** | <Anglian / Severn Trent / etc.> |
| **Issuer (printed name)** | <Site Supervisor / deputy> |
| **Date of issue** | DD/MM/YYYY |
| **Valid from** | DD/MM/YYYY HH:MM |
| **Valid until** | DD/MM/YYYY HH:MM (max 12 hours; re-issue if work continues next day) |
## Section 1 — Activity (tick one)
- [ ] **Excavation** — depth: ____ m; cross-ref MS 2.9 + POL_HSQE_06 Underground Cables + POL_HSQE_13 Excavation
- [ ] **Hot work** — type: ____ (welding / cutting / grinding / brazing / soldering); cross-ref MS 2.24 + SOP 8.15 Fire
- [ ] **Confined space** — space: ____ ; cross-ref MS 3.3 + SOP 8.12 Confined Space
## Section 2 — Hazards identified
| # | Hazard | Source |
|---|--------|--------|
| 1 | … | … |
| 2 | … | … |
## Section 3 — Controls required (tick all that apply)
### Excavation
- [ ] Service drawings obtained and reviewed
- [ ] CAT/genny scan completed; CAT serial: ____ ; battery checked
- [ ] Hand-dig first 600 mm within 1 m of known service
- [ ] Excavation supports identified (battering / shoring / trench box) — type: ____
- [ ] Edge protection rigid (no soft barriers within 2 m)
- [ ] Spoil set back ≥ 1 m
- [ ] Atmospheric testing (deep excavations) — required Y / N
- [ ] Permit holder briefed on emergency egress
### Hot work
- [ ] Combustibles removed or covered with fire-retardant blanket within **10 m radius**
- [ ] Approved fire extinguisher to hand and tested (CO₂ / dry powder for the work type)
- [ ] Ventilation adequate for fume control
- [ ] Power source isolation — provisional shutdown of any flammable supply nearby
- [ ] **Fire watch maintained throughout work AND for 60 minutes after completion**
- [ ] Permit closed only after final fire-watch is complete
### Confined space
- [ ] Risk assessment for confined-space entry on file (MS 3.3)
- [ ] Atmospheric testing before entry: O₂ 19.5–23.5%, LEL <10%, CO <30 ppm, H₂S <10 ppm
- [ ] Continuous monitoring during entry — gas-meter on entrant
- [ ] Top-man (attendant) at entrance — does **not** enter
- [ ] Communication method confirmed (radio / shout-and-respond)
- [ ] Rescue plan agreed; rescue equipment on site (tripod / harness if required)
- [ ] Emergency contact + ambulance route briefed
## Section 4 — Authorisation
| Field | Name | Signature | Date / time |
|-------|------|-----------|-------------|
| **Issuer (Site Supervisor)** | | | |
| **Authorising Director** (high-risk hot work / deep excavation / Confined Space CAT 2+) | | | |
## Section 5 — Permit holder acceptance
By signing, I confirm that I have read this permit, understand the hazards and controls, am competent for the activity, and will work within the permit's limits.
| Name | Role | Signature | Date / time |
|------|------|-----------|-------------|
| | | | |
## Section 6 — Close-out
| Field | Value |
|-------|-------|
| **Time work completed** | DD/MM/YYYY HH:MM |
| **Hot-work fire-watch end** (if hot work) | DD/MM/YYYY HH:MM (must be ≥60 min after completion) |
| **Site reinstated / area handed back** | Y / N |
| **Issues / near-misses during work** | … |
| **Permit holder sign-out** | <name + signature + date/time> |
| **Issuer sign-out** | <name + signature + date/time> |
---
*Filed under `docs/audit-readiness/ptw-records/<YYYY-MM>/ptw-<jobref>.md`.*
Why this matters for the audit¶
Achilles UVDB B2.7.6 (and CDM 2015 Reg 13 for the principal contractor) expects:
- A single coherent permit format (this template) rather than three different scraps for three different activities,
- Issued before work starts, signed by issuer + holder,
- Closed out after work, with hot-work fire-watch evidence captured,
- Retained as part of the job pack.
Spot-sampling: the auditor can pick any recent excavation, hot-work or confined-space job and ask to see the permit. With this template plus the closed-out records folder, the answer is "here it is".
Cross-references¶
- SOP 8.11 — Work at Height (also covers trench-bottom access)
- SOP 8.12 — Confined Space
- SOP 8.15 — Fire Safety (Hot Work Permit warning)
- POL_HSQE_06 — Avoidance of Underground Cables
- POL_HSQE_13 — Excavation